· ANALYTICAL PRINCIPLE:
infrared absorption, at both 3 and 9 microns – on every sample
· RANGE: 0.000 to 0.600 %BAC
[g/210 Liters]; 0.000 to 3.000 mg/liter.
· DIMENSIONS: 14.5” long
x 10” wide x 8.4” deep.
· WEIGHT: 17 lbs [instrument
only].
· CALIBRATION CHECKS: wet
bath simulator or dry gas.
· BAROMETRIC COMPENSATION:
automatic compensation during dry-gas calibration checks.
· DISPLAY: 2 line by 20
character, 8mm character height vacuum fluorescent display.
· PRINTER OPTIONS: thermal,
impact, external
· AUDIBLE BEEPER: gives
auxiliary messages: tones are software-variable in frequency and duration.
· POWER RATINGS:
AC:
90 – 264 VAC, 47 – 63Hz, 1amp max.
Vehicle DC: 10 – 16 VDC, 6 amps max.
· MICROPROCESSOR: Intel compatible x86
based processor @ 30 MHz with a separate DSP
processor for
signal conditioning.
|
· MEMORY: 1 Mbyte for data storage
[expandable to 4 Mbyte]; 1 Mbyte FLASH/SRAM for code/fast access.
Remote program updates.
· REAL-TIME CLOCK: accurate to ±10
minutes per year.
· WARM-UP TIME: less than 20 minutes at
20°C
· TEST TIME: less than 1 minute,
excluding data entry.
· DISPOSABLE MOUTHPIECES: spit-trap
individually wrapped
· COMMUNICATIONS: Three RS-232 serial
ports, one external printer port, internal modem
· CE CERTIFICATION: complies with IEC
1010-1 (1990, 92, 95)
· OIML: complies with OIML R 126 [1998
(E)]
· RFI CERTIFICATION: to BS EN 50081/2-1
97 & EC 95/54/EEC and FCC Part 15 Class B.
· VIBRATION AND SHOCK: to IEC 68-1/2.
· CASE CONSTRUCTION: injection molded
ABS.
· SOFTWARE CONFIGURATION: various
software settings may be configured by the instrument Manager through the
keyboard [via a security password] / through an external PC using COBRA.
|